Free Shipping in the USA on nearly all items!
Limited phone hours during the Holidays! Call us: 888-611-9305
Free Shipping in the USA on nearly ALL items! Limited phone hours during the Holidays!
Spectral power distribution (SPD) is a chart of how much light a source emits at each wavelength. For a grower, it shows the blue, green, red and far-red mix a fixture delivers. It does not show how much light reaches the plant. You need the SPD and the intensity numbers (PPFD and DLI) together, and a measurement at the canopy to confirm both. This guide explains each part in plain terms, so you can read any fixture’s spectrum and match it to your crop.
The Illuminating Engineering Society’s definition, cited in the Encyclopedia of Color Science and Technology, describes SPD as a pictorial representation of the radiant power a source emits at each wavelength or band of wavelengths in the visible region, ideally in watts per nanometer. The same concept can describe light reflected by an object or passing through a material, such as a leaf or a tent wall.
In agriculture, the American Society of Agricultural and Biological Engineers defines SPD in its ANSI/ASABE S640 standard as a list or graph of spectroradiometric values, such as spectral irradiance, over a range of wavelengths. The standard also states that PAR, ultraviolet and far-red SPDs can be measured directly.
Two terms come up constantly:
Every SPD chart has the same two axes. The horizontal axis is wavelength, usually 380 to 780 nm for visible light. The vertical axis is power or intensity. Work through the chart in this order.
The shape also identifies the source type. Metal halide and sodium lamps show sharp spikes, called line spectra. LEDs show smooth peaks and humps. For a broader walk-through of plant lighting basics, this plant lighting guide covers light for indoor plants and how wavelengths relate to them.
One warning about color temperature (CCT, the “3000K” or “5000K” label). Different spectra can land at the same CCT, so a CCT figure cannot tell you what the SPD looks like. Ask for the chart.
The 2023 HortScience grower’s guide to light spectra summarizes how plants respond to each band.
| Band | Range | What it does |
|---|---|---|
| Blue | 400 to 500 nm | Absorbed by chlorophyll. Narrow-band blue increases root dry weight and pigment content. |
| Green | 500 to 600 nm | Present in white light. Plant responses vary sharply with small shifts in center wavelength. |
| Red | 600 to 700 nm | Absorbed by chlorophyll and used efficiently for photosynthesis. |
| Far-red | 700 to about 900 nm | Boosts electron flow in photosystem I and triggers shade-avoidance responses such as longer stems and earlier flowering. |
Virginia Cooperative Extension notes in SPES-823 that high blue light produces smaller leaves and shorter, more compact stems, and that blue is needed for red leaf pigmentation. It adds that most LED fixtures provide less than 20 to 30% blue. A review by Kusuma, Pattison and Bugbee puts the typical horticultural range at 5 to 30% blue to hold back excessive stem extension.
Red photons carry most of the photosynthetic work. The HortScience guide notes that narrow-band red alone can cause “red light syndrome,” with reduced photosynthesis, and that most manufacturers build fixtures around roughly 80% red and 20% blue. Adding blue restores normal photosynthesis within days. That is why single-color red fixtures are rare and mixed spectra dominate.
Far-red acts through the plant’s phytochrome system. In a 2023 Frontiers in Plant Science study, adding far-red at up to 21% of the photon flux to a blue and red spectrum raised light use efficiency in butterhead lettuce by 37 to 43%. Higher far-red levels also changed leaf chemistry. Far-red is a lever to adjust in small steps, and our guide to far-red lighting for indoor growers shows how to test it on a few plants before changing a whole room.
The Illuminating Engineering Society points out in its horticultural LED color guidance that plants react strongly to small shifts in center wavelength. Lettuce shape changed markedly between 510, 520 and 530 nm green LEDs at the same light level. Broad labels such as “red” or “blue” are not enough. The SPD chart is.
Growers often mix these up. Each answers one question.
Plants respond to photon counts, not lumens. Kusuma and colleagues stress that photobiology is driven by the number of photons, and that lumens (a measure tuned to human eyes) misjudge plant light. An SPD lets you calculate photons per wavelength, which is why a good spectrum chart and a PPFD map belong together.
To see how this plays out in a real room, read our explanation of what PPFD per watt actually measures.
Say two fixtures have near-identical normalized SPD charts. Fixture A delivers 600 µmol·m⁻²·s⁻¹ at canopy height, and fixture B delivers 300. The curves look the same, but A gives twice the photons. Run either for 12 hours and the DLI is PPFD × 3,600 seconds × 12 hours ÷ 1,000,000. For A that is about 25.9 mol·m⁻²·d⁻¹. For B it is about 13.0. The spectrum matched. The light dose did not. Our guide to adding hours and PPFD to DLI lays out the same arithmetic.

There is no single correct spectrum. The Resource Innovation Institute’s 2022 lighting best practices guide frames the trade-offs: blue can improve quality and coloration, red drives photosynthesis and yield, and far-red works as a growth regulator. It reports Michigan State University work where more blue light cut lettuce fresh biomass by up to 63%, and that red diodes are the most energy-efficient, so a higher red share raises fixture efficacy.
Here is a practical way to apply that.
The HortScience guide notes that LEDs give complete spectral freedom, but at the cost of consistency between growers. Optimal red-to-blue ratios depend on crop, goal, and the balance between growth rate, biomass, compaction and pigmentation. Treat published ratios as starting points and record what you change.
Spectrum effects also depend on how much of your light is electric. Kusuma and colleagues note spectral effects on plant shape are much greater in sole-source lighting than in greenhouse supplemental lighting, where electric light is a small share. In a tent or room with no sunlight, your fixture’s SPD is the plant’s entire diet.
A datasheet shows what a fixture does under lab conditions. Your canopy sees something different: distance, reflective walls, a second light source and plant height all change it. A spectroradiometer separates light into wavelengths and measures power at each one. StellarNet’s guide to spectrometers explains that the instrument must be calibrated against a source of known output so raw counts become physical units.
Lab testing follows strict geometry. The LRC framework samples spectra at six angles from straight down to 75 degrees, with the luminaire mounted 9 feet up to keep the detector far enough away. At home you cannot copy that setup, but you can follow the same principle: measure at several points at canopy height, and record the same points each time.
Steps for a home or commercial check:
Our full walkthrough covers how to measure PPFD step by step, and the common mistakes section helps you avoid skewed readings.
A spectrum can be ideal on paper and still leave the lower canopy dim. Light that never penetrates the leaves does not drive photosynthesis there. That is the problem our under-canopy systems address: our proprietary proximity systems are designed to improve under-canopy light distribution, and we report increases in yield of over 20% and improved bud grading with them. When you read an SPD, check the spectrum your lower canopy receives as well as the top.
If you want to confirm what is reaching each level, the Mammoth Lighting PAR Meter and Spectrometer reads 380 to 780 nm, plus UV to IR. You can use it to produce your own SPD chart and compare top and lower canopy side by side.
To see fixtures built for this, browse our Under Canopy Grow Lights and Top Lighting collections. Most US orders ship free, and our team gives expert advice to beginners and experienced growers alike.
For tents, kits, environmental controls and accessories, start from the LED Grow Lights Depot home page.
We look at spectrum as one part of a lighting system, not a headline number. A well-shaped SPD tells you what colors a fixture produces. It does not tell you whether the bottom third of the plant gets enough of them.
That is why we build around distribution. Our proprietary proximity systems put light closer to the lower canopy, and we have seen the results in yield and bud grading: over 20% higher yield. A spectrum chart plus a canopy-level measurement is the honest way to judge any setup, and we encourage growers to use both.
For beginners, a complete kit with a tested spectrum removes guesswork. For experienced and commercial growers, top lighting paired with under-canopy lighting gives control over both intensity and distribution. We sell both because rooms differ.
Scott
Spectral distribution describes how a light’s energy is spread across wavelengths. For a grow light, it is the chart showing how much blue, green, red and far-red light the fixture emits. Spectral power distribution is the version that uses power units.
Color temperature summarizes appearance with one number, and many different spectra can match it. Plants respond to specific wavelengths, so the full SPD is more useful for choosing a grow light than CCT alone.
Not automatically. Blue keeps growth compact and supports pigmentation, but too much can make plants look stunted. Virginia Cooperative Extension notes most LED fixtures use less than 20 to 30% blue. Pick the share that matches your crop and stage.
An absolute chart uses W·m⁻²·nm⁻¹ (spectral irradiance), or photon-based units for horticulture. A relative chart shows percent of the peak. Always read the y-axis label before comparing charts from different sources.
Yes. A calibrated spectrometer reads power at each wavelength and draws the chart for you. Measure at canopy height at several points, and repeat after any change in fixture height or dimming.
0 of 3 items selected
Leave a comment